Venturi Flow Meter Calculator

Estimate incompressible venturi-meter flow using throat geometry and a supplied calibration coefficient.

Your flow inputs

mm
mm
kPa
kg/m³
ratio

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Q = Cd × throat area × √[2Δp / (ρ(1−beta⁴))], beta = throat/upstream diameter.

Estimate incompressible venturi-meter flow using throat geometry and a supplied calibration coefficient.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

No gas expansibility, calibration certification, tap correction or cavitation check is provided.

Venturi Flow Meter calculation: inputs and interpretation

Static pressure taps, installation and the meter’s operating range matter. The beta term accounts for finite upstream flow area under the stated model. A throat equal to or larger than the approach diameter is not valid for this calculation.

Discharge and valve coefficients describe a specific device and test basis. The examples are not certified calibrations. Pressure-tap arrangement, density, Reynolds number and downstream conditions can change the relationship between a measured pressure difference and actual flow.

Check the numbers

Venturi Flow Meter Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Upstream internal diameter = 50 mm; Throat internal diameter = 25 mm; Measured static differential = 10 kPa; Fluid density = 998 kg/m³; Meter discharge coefficient = 0.98 ratio.

OutputComputed result
Incompressible venturi estimate133.447768 L/min
Beta ratio0.5 dimensionless
Volume flow SI0.002224 m³/s
Volume flow hourly8.006866 m³/h
US liquid flow35.253171 US GPM
Cubic feet per minute4.712663 CFM

How one input changes the answer

ScenarioChanged inputResult
2.5 kPaMeasured static differential66.723884 L/min
5 kPaMeasured static differential94.361822 L/min
7.5 kPaMeasured static differential115.569157 L/min
10 kPaMeasured static differential133.447768 L/min
15 kPaMeasured static differential163.439469 L/min
20 kPaMeasured static differential188.723643 L/min
30 kPaMeasured static differential231.138314 L/min

Unchanged inputs use: Upstream internal diameter = 50 mm; Throat internal diameter = 25 mm; Measured static differential = 10 kPa; Fluid density = 998 kg/m³; Meter discharge coefficient = 0.98 ratio. Results retain the model limitations described above.

Common questions

Can I use a centerline velocity pressure instead?

No. The input is the appropriate measured static pressure difference for the meter geometry.

Why is beta raised to the fourth power?

Continuity makes velocity proportional to inverse area, and the energy term uses velocity squared.

Does Cd include every installation effect?

Only if an actual calibration or validated specification says so; the default is illustrative.

Can this handle compressible gases?

The present equation is incompressible and lacks a gas expansibility model.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
  • US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html