Flow rate calculators / Valves & flow measurement
Measure flow. Understand the conditions.
Venturi Flow Meter Calculator
Estimate incompressible venturi-meter flow using throat geometry and a supplied calibration coefficient.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Q = Cd × throat area × √[2Δp / (ρ(1−beta⁴))], beta = throat/upstream diameter.
Estimate incompressible venturi-meter flow using throat geometry and a supplied calibration coefficient.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
No gas expansibility, calibration certification, tap correction or cavitation check is provided.
Venturi Flow Meter calculation: inputs and interpretation
Static pressure taps, installation and the meter’s operating range matter. The beta term accounts for finite upstream flow area under the stated model. A throat equal to or larger than the approach diameter is not valid for this calculation.
Discharge and valve coefficients describe a specific device and test basis. The examples are not certified calibrations. Pressure-tap arrangement, density, Reynolds number and downstream conditions can change the relationship between a measured pressure difference and actual flow.
Continue with: Liquid Orifice Flow Calculator · Orifice Diameter from Flow Calculator · Valve Cv Flow Calculator · Required Valve Cv Calculator
Check the numbers
Venturi Flow Meter Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Upstream internal diameter = 50 mm; Throat internal diameter = 25 mm; Measured static differential = 10 kPa; Fluid density = 998 kg/m³; Meter discharge coefficient = 0.98 ratio.
| Output | Computed result |
|---|---|
| Incompressible venturi estimate | 133.447768 L/min |
| Beta ratio | 0.5 dimensionless |
| Volume flow SI | 0.002224 m³/s |
| Volume flow hourly | 8.006866 m³/h |
| US liquid flow | 35.253171 US GPM |
| Cubic feet per minute | 4.712663 CFM |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 2.5 kPa | Measured static differential | 66.723884 L/min |
| 5 kPa | Measured static differential | 94.361822 L/min |
| 7.5 kPa | Measured static differential | 115.569157 L/min |
| 10 kPa | Measured static differential | 133.447768 L/min |
| 15 kPa | Measured static differential | 163.439469 L/min |
| 20 kPa | Measured static differential | 188.723643 L/min |
| 30 kPa | Measured static differential | 231.138314 L/min |
Unchanged inputs use: Upstream internal diameter = 50 mm; Throat internal diameter = 25 mm; Measured static differential = 10 kPa; Fluid density = 998 kg/m³; Meter discharge coefficient = 0.98 ratio. Results retain the model limitations described above.
Common questions
Can I use a centerline velocity pressure instead?
No. The input is the appropriate measured static pressure difference for the meter geometry.
Why is beta raised to the fourth power?
Continuity makes velocity proportional to inverse area, and the energy term uses velocity squared.
Does Cd include every installation effect?
Only if an actual calibration or validated specification says so; the default is illustrative.
Can this handle compressible gases?
The present equation is incompressible and lacks a gas expansibility model.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
- US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html