Flow rate calculators / Valves & flow measurement
Measure flow. Understand the conditions.
Orifice Diameter from Flow Calculator
Invert the simple liquid-orifice model to estimate opening diameter for a target flow.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Opening area = Q/[Cd√(2Δp/ρ)]; diameter = √(4 area/π).
Invert the simple liquid-orifice model to estimate opening diameter for a target flow.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
This is a preliminary incompressible opening calculation, not a control-valve, cavitation or gas-capacity design.
Orifice Diameter from Flow calculation: inputs and interpretation
The result is an ideal round opening under the supplied coefficient and differential pressure. A manufactured nozzle may have a different effective area and calibrated coefficient. Convert the required flow to local volume flow before comparing with a product rating.
Discharge and valve coefficients describe a specific device and test basis. The examples are not certified calibrations. Pressure-tap arrangement, density, Reynolds number and downstream conditions can change the relationship between a measured pressure difference and actual flow.
Continue with: Liquid Orifice Flow Calculator · Venturi Flow Meter Calculator · Valve Cv Flow Calculator · Required Valve Cv Calculator
Check the numbers
Orifice Diameter from Flow Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Volumetric flow = 60 L/min; Pressure difference = 100 kPa; Fluid density = 998 kg/m³; Discharge coefficient = 0.62 ratio.
| Output | Computed result |
|---|---|
| Theoretical opening diameter | 12.044377 mm |
| Opening area | 0.000114 m² |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 15 L/min | Volumetric flow | 6.022189 mm |
| 30 L/min | Volumetric flow | 8.516661 mm |
| 45 L/min | Volumetric flow | 10.430737 mm |
| 60 L/min | Volumetric flow | 12.044377 mm |
| 90 L/min | Volumetric flow | 14.751289 mm |
| 120 L/min | Volumetric flow | 17.033322 mm |
| 180 L/min | Volumetric flow | 20.861473 mm |
Unchanged inputs use: Volumetric flow = 60 L/min; Pressure difference = 100 kPa; Fluid density = 998 kg/m³; Discharge coefficient = 0.62 ratio. Results retain the model limitations described above.
Common questions
Does it select a standard drill or nozzle size?
No. It reports a continuous theoretical diameter; verify a real product’s measured performance.
What if the pressure difference is zero?
A positive target flow cannot be obtained from this finite passive-orifice model at zero differential pressure.
Can I use it for an air-flow orifice?
Not for compressible conditions. Gas density and choking require a suitable model.
Should I include a pipe beta ratio?
This simple large-upstream-area model does not include that effect. Use an appropriate meter equation for a finite approach pipe.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf