Liquid Orifice Flow Calculator
Calculate an incompressible free-orifice estimate from opening size, differential pressure, density and Cd.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Q = Cd × opening area × √(2Δp/ρ).
Calculate an incompressible free-orifice estimate from opening size, differential pressure, density and Cd.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
Not a cavitating-liquid, choked-gas, steam or safety-valve sizing model.
Liquid Orifice Flow calculation: inputs and interpretation
The opening-area equation treats the upstream reservoir or supply section as large relative to the opening. A finite pipe-mounted orifice meter needs a beta-ratio correction and calibrated tap geometry. The chosen Cd is illustrative and must fit the device and operating range.
Discharge and valve coefficients describe a specific device and test basis. The examples are not certified calibrations. Pressure-tap arrangement, density, Reynolds number and downstream conditions can change the relationship between a measured pressure difference and actual flow.
Continue with: Orifice Diameter from Flow Calculator · Venturi Flow Meter Calculator · Valve Cv Flow Calculator · Required Valve Cv Calculator
Check the numbers
Liquid Orifice Flow Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Orifice opening diameter = 10 mm; Pressure difference = 100 kPa; Fluid density = 998 kg/m³; Discharge coefficient = 0.62 ratio.
| Output | Computed result |
|---|---|
| Simple liquid-orifice estimate | 41.360192 L/min |
| Volume flow SI | 0.000689 m³/s |
| Volume flow hourly | 2.481612 m³/h |
| US liquid flow | 10.926207 US GPM |
| Cubic feet per minute | 1.460621 CFM |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 25 kPa | Pressure difference | 20.680096 L/min |
| 50 kPa | Pressure difference | 29.246072 L/min |
| 75 kPa | Pressure difference | 35.818977 L/min |
| 100 kPa | Pressure difference | 41.360192 L/min |
| 150 kPa | Pressure difference | 50.655683 L/min |
| 200 kPa | Pressure difference | 58.492145 L/min |
| 300 kPa | Pressure difference | 71.637954 L/min |
Unchanged inputs use: Orifice opening diameter = 10 mm; Pressure difference = 100 kPa; Fluid density = 998 kg/m³; Discharge coefficient = 0.62 ratio. Results retain the model limitations described above.
Common questions
Can I use this for compressed air through an orifice?
Not when compressibility matters. Use the gas nozzle tool within its own ideal-gas limits.
Is Cd always 0.62?
No. Geometry, Reynolds number and test conditions affect the coefficient.
Does the pressure input mean upstream gauge pressure?
It is the relevant pressure difference across the modeled opening, not an arbitrary supply reading.
Is an orifice meter the same as a reservoir opening?
No. A pipe meter also needs approach-area and pressure-tap effects.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
- US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html