Flow rate calculators / Valves & flow measurement
Measure flow. Understand the conditions.
Valve Cv Flow Calculator
Calculate the simple nonchoked liquid Cv relationship in its stated US unit basis.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Liquid flow US GPM = Cv × √(pressure drop psi / specific gravity).
Calculate the simple nonchoked liquid Cv relationship in its stated US unit basis.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
This does not implement IEC/ISA gas sizing, flashing or choked-liquid corrections.
Valve Cv Flow calculation: inputs and interpretation
Cv is defined using a particular water-reference convention, and the simple square-root relation is not the complete control-valve sizing procedure. Real valve selection can require recovery factors, viscosity corrections, reducers, noise and cavitation analysis.
Discharge and valve coefficients describe a specific device and test basis. The examples are not certified calibrations. Pressure-tap arrangement, density, Reynolds number and downstream conditions can change the relationship between a measured pressure difference and actual flow.
Continue with: Liquid Orifice Flow Calculator · Orifice Diameter from Flow Calculator · Venturi Flow Meter Calculator · Required Valve Cv Calculator
Check the numbers
Valve Cv Flow Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Valve flow coefficient Cv = 5 US basis; Valve pressure difference = 10 psi; Liquid specific gravity = 1 water-relative.
| Output | Computed result |
|---|---|
| Simple liquid Cv flow | 15.811388 US GPM |
| Volume flow SI | 0.000998 m³/s |
| Volume flow hourly | 3.591157 m³/h |
| US liquid flow | 15.811388 US GPM |
| Cubic feet per minute | 2.113675 CFM |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 2.5 psi | Valve pressure difference | 7.905694 US GPM |
| 5 psi | Valve pressure difference | 11.18034 US GPM |
| 7.5 psi | Valve pressure difference | 13.693064 US GPM |
| 10 psi | Valve pressure difference | 15.811388 US GPM |
| 15 psi | Valve pressure difference | 19.364917 US GPM |
| 20 psi | Valve pressure difference | 22.36068 US GPM |
| 30 psi | Valve pressure difference | 27.386128 US GPM |
Unchanged inputs use: Valve flow coefficient Cv = 5 US basis; Valve pressure difference = 10 psi; Liquid specific gravity = 1 water-relative. Results retain the model limitations described above.
Common questions
Is Cv the same as Kv?
No. Their reference volume and pressure units differ. Use the dedicated coefficient conversion or a matching valve specification.
Can I calculate gas flow using this liquid formula?
No. A compressible valve model requires more parameters and can be choked.
Does this predict a valve position?
Not without its actual coefficient-versus-travel characteristic.
Is pressure drop the same as inlet pressure?
No. It is the modeled differential across the valve, with the required test/flow basis.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- Emerson Control Valve Handbook, Chapter 5: liquid and gas sizing boundarieshttps://www.emerson.com/is/content/emerson/it/final-control/flow-controls/valves/documents/control-valve-handbook-en-3661206.pdf
- NIST SP 811 Appendix B.9: volume, mass and flow unit factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9