Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Open channels & drainage

Measure flow. Understand the conditions.

V-Notch Weir Flow Calculator

Estimate a free triangular-weir discharge using notch angle, head and a supplied coefficient.

Your flow inputs

degrees
m
ratio

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Idealized Q = (8/15) Cd √(2g) tan(full notch angle/2) × head^(5/2).

Estimate a free triangular-weir discharge using notch angle, head and a supplied coefficient.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Does not implement all named standard-weir calibrations or submergence corrections.

V-Notch Weir Flow calculation: inputs and interpretation

The entered angle spans both notch faces. Head is measured from the apex to the appropriate upstream surface datum. Sharpness, ventilation, side clearance and calibration range affect the validity of an actual installation.

Uniform-flow and free-overfall formulas have operating limits. A backwater, hydraulic jump, submerged outlet or inlet-controlled culvert may require a different analysis. Roughness and discharge coefficients are explicit inputs rather than universal material guarantees.

Check the numbers

V-Notch Weir Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Full notch angle = 90 degrees; Head above notch apex = 0.2 m; Applicable discharge coefficient = 0.6 ratio.

OutputComputed result
Free V-notch coefficient estimate0.025351 m³/s
Volume flow SI0.025351 m³/s
Volume flow hourly91.264694 m³/h
US liquid flow401.82636 US GPM
Cubic feet per minute53.716371 CFM

How one input changes the answer

ScenarioChanged inputResult
0.05 mHead above notch apex0.000792 m³/s
0.1 mHead above notch apex0.004482 m³/s
0.15 mHead above notch apex0.01235 m³/s
0.2 mHead above notch apex0.025351 m³/s
0.3 mHead above notch apex0.06986 m³/s
0.4 mHead above notch apex0.143409 m³/s
0.6 mHead above notch apex0.395188 m³/s

Unchanged inputs use: Full notch angle = 90 degrees; Head above notch apex = 0.2 m; Applicable discharge coefficient = 0.6 ratio. Results retain the model limitations described above.

Common questions

Can I use a 90-degree V-notch?

Yes in this coefficient model, when the stated free-flow assumptions and suitable coefficient are justified.

Is the angle half the notch opening?

No. Enter the full angle; the equation halves it inside the tangent.

Why is head raised to 2.5?

The ideal integration includes both changing opening width and velocity with head.

Can I calculate a circular weir here?

No. A circular opening has different geometry and needs an applicable calibrated relationship.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US Bureau of Reclamation Water Measurement Manual, Chapter 7: weirs and operating conditionshttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_04.html
  • US Bureau of Reclamation: conditions for sharp-crested weirshttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_05.html