Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Open channels & drainage

Measure flow. Understand the conditions.

Trapezoidal Channel Flow Calculator

Calculate uniform open-channel discharge for a trapezoidal section and explicit side slope.

Your flow inputs

m
m
H:V
SI basis
m/m

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Area=y(b+zy); wetted perimeter=b+2y√(1+z²); SI Q=A R^(2/3) √S/n.

Calculate uniform open-channel discharge for a trapezoidal section and explicit side slope.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

No freeboard, erosion protection, backwater or unstable-bank design is performed.

Trapezoidal Channel Flow calculation: inputs and interpretation

The side-slope input is horizontal distance per unit vertical rise. A value of two means 2H:1V on each side, not an angle in degrees. Both banks are assumed symmetric, and the bottom is flat across the entered width.

Uniform-flow and free-overfall formulas have operating limits. A backwater, hydraulic jump, submerged outlet or inlet-controlled culvert may require a different analysis. Roughness and discharge coefficients are explicit inputs rather than universal material guarantees.

Check the numbers

Trapezoidal Channel Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Bottom width = 1 m; Flow depth = 0.5 m; Side slope horizontal per vertical = 1 H:V; Manning roughness n = 0.013 SI basis; Energy slope = 0.001 m/m.

OutputComputed result
Uniform-channel Manning discharge0.836838 m³/s
Wetted area0.75 m²
Hydraulic radius0.31066 m
Mean velocity1.115785 m/s
Volume flow SI0.836838 m³/s
Volume flow hourly3,012.618444 m³/h
US liquid flow13,264.159953 US GPM
Cubic feet per minute1,773.160272 CFM

How one input changes the answer

ScenarioChanged inputResult
0.125 mFlow depth0.075598 m³/s
0.25 mFlow depth0.245075 m³/s
0.375 mFlow depth0.498053 m³/s
0.5 mFlow depth0.836838 m³/s
0.75 mFlow depth1.791967 m³/s
1 mFlow depth3.155681 m³/s
1.5 mFlow depth7.295841 m³/s

Unchanged inputs use: Bottom width = 1 m; Flow depth = 0.5 m; Side slope horizontal per vertical = 1 H:V; Manning roughness n = 0.013 SI basis; Energy slope = 0.001 m/m. Results retain the model limitations described above.

Common questions

Can I enter a triangular channel?

This form requires a positive bottom width. A separate triangular approximation or a suitable model is needed for a zero-width apex.

What does 1H:1V mean?

Each side extends one horizontal unit for one vertical unit of depth.

Does the model use top width as the bottom width?

No. Enter the actual bottom width; top width is b+2zy.

Does calculated flow guarantee erosion resistance?

No. Material behavior and permissible shear/velocity require separate assessment.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US National Weather Service: Normal Depth Demonstration Tool and Manning equationhttps://www.weather.gov/aprfc/normaldepthcalc
  • US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html