Your flow inputs

m
m
SI basis
m/m

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

theta=2 acos(1−2y/D); area=D²(theta−sin theta)/8; wetted perimeter=D theta/2; Q=A R^(2/3)√S/n.

Apply circular-segment geometry and SI Manning flow to a specified partly full gravity pipe.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Not a sewer network, surcharge, air-entrapment or inlet/outlet-control solution.

Partially Full Pipe Flow calculation: inputs and interpretation

The central angle is in radians, and only the wetted arc contributes to the perimeter. The calculation approaches the full circular geometry at depth equal to diameter, but a truly pressurized pipe requires a pressure-flow analysis. Water depth cannot exceed the actual internal diameter.

Uniform-flow and free-overfall formulas have operating limits. A backwater, hydraulic jump, submerged outlet or inlet-controlled culvert may require a different analysis. Roughness and discharge coefficients are explicit inputs rather than universal material guarantees.

Check the numbers

Partially Full Pipe Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Circular internal diameter = 0.3 m; Water depth above invert = 0.15 m; Manning roughness n = 0.013 SI basis; Energy slope = 0.001 m/m.

OutputComputed result
Circular open-section Manning discharge0.01529 m³/s
Wetted area0.035343 m²
Hydraulic radius0.075 m
Depth / diameter0.5 ratio
Volume flow SI0.01529 m³/s
Volume flow hourly55.043037 m³/h
US liquid flow242.3472 US GPM
Cubic feet per minute32.397108 CFM

How one input changes the answer

ScenarioChanged inputResult
0.0375 mWater depth above invert0.001018 m³/s
0.075 mWater depth above invert0.004189 m³/s
0.1125 mWater depth above invert0.009149 m³/s
0.15 mWater depth above invert0.01529 m³/s
0.225 mWater depth above invert0.027885 m³/s
0.3 mWater depth above invert0.030579 m³/s

Unchanged inputs use: Circular internal diameter = 0.3 m; Water depth above invert = 0.15 m; Manning roughness n = 0.013 SI basis; Energy slope = 0.001 m/m. Results retain the model limitations described above.

Common questions

Is flow proportional to the depth fraction?

No. Both area and hydraulic radius change nonlinearly with depth.

Can I enter depth greater than diameter?

No. That is outside the circular open-section geometry.

Does it calculate full pressurized flow?

No. Even the full-depth limit is a Manning uniform-flow representation, not a pressure-network model.

Can I determine normal depth here?

This tool evaluates a given depth. The normal-depth tool solves a supported trapezoidal section from specified flow.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US National Weather Service: Normal Depth Demonstration Tool and Manning equationhttps://www.weather.gov/aprfc/normaldepthcalc
  • US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html