Flow rate calculators / Open channels & drainage
Measure flow. Understand the conditions.
Rectangular Weir Flow Calculator
Estimate free-overfall rectangular-weir discharge with an explicitly supplied coefficient.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Free sharp-crest idealized Q = (2/3) Cd × width × √(2g) × head^(3/2).
Estimate free-overfall rectangular-weir discharge with an explicitly supplied coefficient.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
Not a submerged-weir, calibrated standard-weir table or complete structure design.
Rectangular Weir Flow calculation: inputs and interpretation
Use upstream measured head above the crest, not water depth at the falling nappe. A fully ventilated free nappe and appropriate approach conditions are important. End contractions, approach velocity and published calibration limits must be represented by a suitable validated procedure rather than assumed away.
Uniform-flow and free-overfall formulas have operating limits. A backwater, hydraulic jump, submerged outlet or inlet-controlled culvert may require a different analysis. Roughness and discharge coefficients are explicit inputs rather than universal material guarantees.
Continue with: Rectangular Channel Flow Calculator · Trapezoidal Channel Flow Calculator · Partially Full Pipe Flow Calculator · Normal Depth Calculator
Check the numbers
Rectangular Weir Flow Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Effective crest width = 0.5 m; Upstream head above crest = 0.2 m; Applicable discharge coefficient = 0.62 ratio.
| Output | Computed result |
|---|---|
| Free rectangular-weir coefficient estimate | 0.081864 m³/s |
| Volume flow SI | 0.081864 m³/s |
| Volume flow hourly | 294.708909 m³/h |
| US liquid flow | 1,297.564289 US GPM |
| Cubic feet per minute | 173.459115 CFM |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 0.05 m | Upstream head above crest | 0.010233 m³/s |
| 0.1 m | Upstream head above crest | 0.028943 m³/s |
| 0.15 m | Upstream head above crest | 0.053172 m³/s |
| 0.2 m | Upstream head above crest | 0.081864 m³/s |
| 0.3 m | Upstream head above crest | 0.150393 m³/s |
| 0.4 m | Upstream head above crest | 0.231545 m³/s |
| 0.6 m | Upstream head above crest | 0.425376 m³/s |
Unchanged inputs use: Effective crest width = 0.5 m; Upstream head above crest = 0.2 m; Applicable discharge coefficient = 0.62 ratio. Results retain the model limitations described above.
Common questions
Does this implement every USBR rectangular-weir calibration?
No. It is the stated coefficient form; actual standard calibration and operating limits must be selected separately.
Can I use total channel depth as head?
Only if it is actually the correct upstream height above the crest datum.
Does downstream submergence matter?
Yes. The free-overfall equation can become inappropriate when tailwater affects discharge.
Is Cd a fixed universal constant?
No. Use a coefficient and calibration applicable to the geometry and conditions.
Does this include a Parshall flume, circular weir or Cipolletti weir calculator?
No. Those devices use geometry and calibration relationships specific to their type and operating conditions. This page implements only the stated free-flow rectangular sharp-crested model with an explicit coefficient; changing the name does not change the equation.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- US Bureau of Reclamation Water Measurement Manual, Chapter 7: weirs and operating conditionshttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_04.html
- US Bureau of Reclamation: conditions for sharp-crested weirshttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_05.html