Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Open channels & drainage

Measure flow. Understand the conditions.

Rectangular Weir Flow Calculator

Estimate free-overfall rectangular-weir discharge with an explicitly supplied coefficient.

Your flow inputs

m
m
ratio

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Free sharp-crest idealized Q = (2/3) Cd × width × √(2g) × head^(3/2).

Estimate free-overfall rectangular-weir discharge with an explicitly supplied coefficient.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Not a submerged-weir, calibrated standard-weir table or complete structure design.

Rectangular Weir Flow calculation: inputs and interpretation

Use upstream measured head above the crest, not water depth at the falling nappe. A fully ventilated free nappe and appropriate approach conditions are important. End contractions, approach velocity and published calibration limits must be represented by a suitable validated procedure rather than assumed away.

Uniform-flow and free-overfall formulas have operating limits. A backwater, hydraulic jump, submerged outlet or inlet-controlled culvert may require a different analysis. Roughness and discharge coefficients are explicit inputs rather than universal material guarantees.

Check the numbers

Rectangular Weir Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Effective crest width = 0.5 m; Upstream head above crest = 0.2 m; Applicable discharge coefficient = 0.62 ratio.

OutputComputed result
Free rectangular-weir coefficient estimate0.081864 m³/s
Volume flow SI0.081864 m³/s
Volume flow hourly294.708909 m³/h
US liquid flow1,297.564289 US GPM
Cubic feet per minute173.459115 CFM

How one input changes the answer

ScenarioChanged inputResult
0.05 mUpstream head above crest0.010233 m³/s
0.1 mUpstream head above crest0.028943 m³/s
0.15 mUpstream head above crest0.053172 m³/s
0.2 mUpstream head above crest0.081864 m³/s
0.3 mUpstream head above crest0.150393 m³/s
0.4 mUpstream head above crest0.231545 m³/s
0.6 mUpstream head above crest0.425376 m³/s

Unchanged inputs use: Effective crest width = 0.5 m; Upstream head above crest = 0.2 m; Applicable discharge coefficient = 0.62 ratio. Results retain the model limitations described above.

Common questions

Does this implement every USBR rectangular-weir calibration?

No. It is the stated coefficient form; actual standard calibration and operating limits must be selected separately.

Can I use total channel depth as head?

Only if it is actually the correct upstream height above the crest datum.

Does downstream submergence matter?

Yes. The free-overfall equation can become inappropriate when tailwater affects discharge.

Is Cd a fixed universal constant?

No. Use a coefficient and calibration applicable to the geometry and conditions.

Does this include a Parshall flume, circular weir or Cipolletti weir calculator?

No. Those devices use geometry and calibration relationships specific to their type and operating conditions. This page implements only the stated free-flow rectangular sharp-crested model with an explicit coefficient; changing the name does not change the equation.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US Bureau of Reclamation Water Measurement Manual, Chapter 7: weirs and operating conditionshttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_04.html
  • US Bureau of Reclamation: conditions for sharp-crested weirshttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_05.html