Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Valves & flow measurement

Measure flow. Understand the conditions.

Nozzle K-Factor Flow Calculator

Calculate a supplied square-root nozzle flow relationship using matching coefficient units.

Your flow inputs

US GPM/√psi
psi

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

US GPM = calibrated K × √(pressure psi).

Calculate a supplied square-root nozzle flow relationship using matching coefficient units.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

No coverage, fire-design adequacy, spray pattern or certification is evaluated.

Nozzle K-Factor Flow calculation: inputs and interpretation

The coefficient must describe the actual nozzle and applicable pressure definition. A fire sprinkler or industrial spray product can have different ratings and installation constraints. The example K is an arithmetic input rather than a product selection or required value.

Discharge and valve coefficients describe a specific device and test basis. The examples are not certified calibrations. Pressure-tap arrangement, density, Reynolds number and downstream conditions can change the relationship between a measured pressure difference and actual flow.

Check the numbers

Nozzle K-Factor Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Calibrated nozzle K-factor = 5.6 US GPM/√psi; Relevant nozzle pressure = 20 psi.

OutputComputed result
Calibrated K-factor nozzle flow25.043961 US GPM
Volume flow SI0.00158 m³/s
Volume flow hourly5.688102 m³/h
US liquid flow25.043961 US GPM
Cubic feet per minute3.347891 CFM

How one input changes the answer

ScenarioChanged inputResult
5 psiRelevant nozzle pressure12.521981 US GPM
10 psiRelevant nozzle pressure17.708755 US GPM
15 psiRelevant nozzle pressure21.688707 US GPM
20 psiRelevant nozzle pressure25.043961 US GPM
30 psiRelevant nozzle pressure30.672463 US GPM
40 psiRelevant nozzle pressure35.41751 US GPM
60 psiRelevant nozzle pressure43.377413 US GPM

Unchanged inputs use: Calibrated nozzle K-factor = 5.6 US GPM/√psi; Relevant nozzle pressure = 20 psi. Results retain the model limitations described above.

Common questions

Can I use a metric K-factor unchanged?

No. K includes flow and pressure units, so the numerical coefficient must match this US GPM/√psi basis.

Does pressure alone determine nozzle flow?

Only with a suitable calibrated nozzle relationship and known coefficient.

Does this size a fire sprinkler system?

No. It calculates one nozzle relationship and does not implement a fire-protection design standard.

Does it apply to choked gas nozzles?

No. Gas choking requires a compressible model.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
  • NIST SP 811 Appendix B.9: volume, mass and flow unit factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9