Flow rate calculators / Valves & flow measurement
Measure flow. Understand the conditions.
Differential Pressure Flow Calculator
Apply a calibrated square-root differential-pressure flow relationship at constant density.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Q = reference Q × √(current differential / reference differential), at unchanged density and meter conditions.
Apply a calibrated square-root differential-pressure flow relationship at constant density.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
This scales one supplied reference point; it does not calibrate an unknown meter or compensate steam/gas properties.
Differential Pressure Flow calculation: inputs and interpretation
A DP transmitter may already output a square-root-extracted flow signal. Do not apply the square root twice. Zero offsets, density changes and the valid turndown range affect the interpretation of a small differential.
Discharge and valve coefficients describe a specific device and test basis. The examples are not certified calibrations. Pressure-tap arrangement, density, Reynolds number and downstream conditions can change the relationship between a measured pressure difference and actual flow.
Continue with: Liquid Orifice Flow Calculator · Orifice Diameter from Flow Calculator · Venturi Flow Meter Calculator · Valve Cv Flow Calculator
Check the numbers
Differential Pressure Flow Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Flow at reference differential = 100 L/min; Reference differential pressure = 100 kPa; Current differential pressure = 25 kPa.
| Output | Computed result |
|---|---|
| Reference-scaled DP flow | 50 L/min |
| Differential fraction | 25 % |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 6.25 kPa | Current differential pressure | 25 L/min |
| 12.5 kPa | Current differential pressure | 35.355339 L/min |
| 18.75 kPa | Current differential pressure | 43.30127 L/min |
| 25 kPa | Current differential pressure | 50 L/min |
| 37.5 kPa | Current differential pressure | 61.237244 L/min |
| 50 kPa | Current differential pressure | 70.710678 L/min |
| 75 kPa | Current differential pressure | 86.60254 L/min |
Unchanged inputs use: Flow at reference differential = 100 L/min; Reference differential pressure = 100 kPa; Current differential pressure = 25 kPa. Results retain the model limitations described above.
Common questions
Is 25% differential equal to 25% flow?
Under this square-root relationship it corresponds to 50% of reference flow.
Does a 4–20 mA signal always represent DP linearly?
No. Verify whether the configured transmitter output represents DP or already-linearized flow.
Can I use it for changing-density gas?
Not without an appropriate density correction and meter model.
Does it implement an Emerson instrument model?
No. It uses only the entered reference relationship.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
- Emerson Control Valve Handbook, Chapter 5: liquid and gas sizing boundarieshttps://www.emerson.com/is/content/emerson/it/final-control/flow-controls/valves/documents/control-valve-handbook-en-3661206.pdf