Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Open channels & drainage

Measure flow. Understand the conditions.

Confined Aquifer Radial Flow Calculator

Apply a simplified Thiem confined-aquifer relationship to two observation radii.

Your flow inputs

m/s
m
m
m
m

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Steady confined-flow magnitude Q = 2π × conductivity × thickness × head difference / ln(outer radius/inner radius).

Apply a simplified Thiem confined-aquifer relationship to two observation radii.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Not a sustainable-yield approval or interpretation of an arbitrary transient well test.

Confined Aquifer Radial Flow calculation: inputs and interpretation

The model assumes steady radial flow in an ideal confined aquifer with compatible observation heads. The outer radius must exceed the inner radius. Actual pumping tests can require transient, boundary, leakage or partial-penetration analysis.

Uniform-flow and free-overfall formulas have operating limits. A backwater, hydraulic jump, submerged outlet or inlet-controlled culvert may require a different analysis. Roughness and discharge coefficients are explicit inputs rather than universal material guarantees.

Check the numbers

Confined Aquifer Radial Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Hydraulic conductivity = 0.0001 m/s; Confined aquifer thickness = 10 m; Positive head difference = 1 m; Inner observation radius = 1 m; Outer observation radius = 100 m.

OutputComputed result
Steady confined radial flow0.001364 m³/s
Volume flow SI0.001364 m³/s
Volume flow hourly4.911755 m³/h
US liquid flow21.625806 US GPM
Cubic feet per minute2.89095 CFM

How one input changes the answer

ScenarioChanged inputResult
0.25 mPositive head difference0.000341 m³/s
0.5 mPositive head difference0.000682 m³/s
0.75 mPositive head difference0.001023 m³/s
1 mPositive head difference0.001364 m³/s
1.5 mPositive head difference0.002047 m³/s
2 mPositive head difference0.002729 m³/s
3 mPositive head difference0.004093 m³/s

Unchanged inputs use: Hydraulic conductivity = 0.0001 m/s; Confined aquifer thickness = 10 m; Positive head difference = 1 m; Inner observation radius = 1 m; Outer observation radius = 100 m. Results retain the model limitations described above.

Common questions

Can I use it for an unconfined aquifer?

Not directly. The unconfined relationship differs.

What does the head difference mean?

Use the appropriate positive head difference between the two stated observation locations under the model.

Can the radii be equal?

No. The logarithmic denominator would be zero.

Does this determine aquifer conductivity from one guessed flow?

No. This page computes discharge from the supplied parameters without test inversion or uncertainty analysis.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • USGS Open-File Report 90-183: Darcy flow and the Thiem confined-radial-flow derivationhttps://pubs.usgs.gov/of/1990/ofr90-183/pdf/ofr_90-183_e.pdf