Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Open channels & drainage

Measure flow. Understand the conditions.

Broad-Crested Weir Calculator

Estimate a broad-crest discharge from an ideal critical-control relationship and explicit coefficient.

Your flow inputs

m
m
ratio

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Ideal rectangular critical-crest Q = Cd × width × √g × (2H/3)^(3/2).

Estimate a broad-crest discharge from an ideal critical-control relationship and explicit coefficient.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Not a submerged structure, dam-safety or complete weir design calculation.

Broad-Crested Weir calculation: inputs and interpretation

The head here is the appropriate upstream specific-energy head relative to crest elevation. Whether a real crest is long enough, aerated and free from downstream control must be established separately. The coefficient is a chosen scenario value, not a universal calibration.

Uniform-flow and free-overfall formulas have operating limits. A backwater, hydraulic jump, submerged outlet or inlet-controlled culvert may require a different analysis. Roughness and discharge coefficients are explicit inputs rather than universal material guarantees.

Check the numbers

Broad-Crested Weir Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Crest flow width = 1 m; Upstream specific head above crest = 0.3 m; Chosen coefficient = 0.95 ratio.

OutputComputed result
Ideal broad-crest coefficient estimate0.26609 m³/s
Volume flow SI0.26609 m³/s
Volume flow hourly957.924845 m³/h
US liquid flow4,217.616205 US GPM
Cubic feet per minute563.813277 CFM

How one input changes the answer

ScenarioChanged inputResult
0.075 mUpstream specific head above crest0.033261 m³/s
0.15 mUpstream specific head above crest0.094077 m³/s
0.225 mUpstream specific head above crest0.172831 m³/s
0.3 mUpstream specific head above crest0.26609 m³/s
0.45 mUpstream specific head above crest0.488839 m³/s
0.6 mUpstream specific head above crest0.752617 m³/s
0.9 mUpstream specific head above crest1.382645 m³/s

Unchanged inputs use: Crest flow width = 1 m; Upstream specific head above crest = 0.3 m; Chosen coefficient = 0.95 ratio. Results retain the model limitations described above.

Common questions

Is this the same as a sharp-crested rectangular weir?

No. The critical-crest model and its coefficient definition differ.

Does crest length along flow matter?

Yes to whether the physical structure meets the model assumptions, although it is not a correction input here.

Can I use a water-level reading as total specific head?

Only if approach-velocity and reference-datum effects are handled appropriately.

Does this select a safe structure size?

No. It evaluates a stated hydraulic model only.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US Bureau of Reclamation Water Measurement Manual, Chapter 7: weirs and operating conditionshttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_04.html
  • US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf