Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Pumps & water systems

Measure flow. Understand the conditions.

Well Recovery Rate Calculator

Calculate a cylindrical-well storage recovery rate from a measured level rise.

Your flow inputs

mm
m
min

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Observed casing storage recovery = casing area × level rise / elapsed time.

Calculate a cylindrical-well storage recovery rate from a measured level rise.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Not a complete pumping test, groundwater permit or sustainable-yield determination.

Well Recovery Rate calculation: inputs and interpretation

This measures change in the water stored in the modeled casing, not automatically sustainable aquifer yield. Well geometry, open intervals, ongoing inflow/outflow and test history can make the storage estimate unrepresentative of long-term pumping capability.

A pump operates where its curve meets the system curve. The tools here isolate a stated energy, displacement or test relationship; they do not automatically select a pump or verify suction conditions, cavitation margin, protection or installation requirements.

Check the numbers

Well Recovery Rate Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Cylindrical casing internal diameter = 150 mm; Observed water-level rise = 2 m; Observation duration = 30 min.

OutputComputed result
Observed casing storage recovery1.178097 L/min
Recovered modeled storage35.342917 L
Volume flow SI1.963495e-5 m³/s
Volume flow hourly0.070686 m³/h
US liquid flow0.31122 US GPM
Cubic feet per minute0.041604 CFM

How one input changes the answer

ScenarioChanged inputResult
0.5 mObserved water-level rise0.294524 L/min
1 mObserved water-level rise0.589049 L/min
1.5 mObserved water-level rise0.883573 L/min
2 mObserved water-level rise1.178097 L/min
3 mObserved water-level rise1.767146 L/min
4 mObserved water-level rise2.356194 L/min
6 mObserved water-level rise3.534292 L/min

Unchanged inputs use: Cylindrical casing internal diameter = 150 mm; Observed water-level rise = 2 m; Observation duration = 30 min. Results retain the model limitations described above.

Common questions

Is recovery rate the same as sustainable well yield?

No. A casing storage observation is only one limited part of well behavior.

What diameter should I use?

The actual internal water-storage diameter, not a nominal outside casing dimension.

What if the bore is irregular?

The simple cylindrical storage volume may be wrong; use appropriate geometry or test interpretation.

Does this include water pumped during recovery?

No. The calculation assumes the supplied level change and duration describe the intended storage observation without unmodeled withdrawals.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html
  • NIST SP 811 Appendix B.9: volume, mass and flow unit factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9