Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Pumps & water systems

Measure flow. Understand the conditions.

Pump Flow from Power Calculator

Invert the hydraulic-power balance for a specified positive head and efficiency.

Your flow inputs

kW
%
m
kg/m³

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Q = input W × efficiency / (density × g × head).

Invert the hydraulic-power balance for a specified positive head and efficiency.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

The result does not prove that a real pump can reach the calculated operating point.

Pump Flow from Power calculation: inputs and interpretation

A 3 HP or 1 kW nameplate alone cannot tell the operating flow. This page additionally requires differential head and a justified efficiency, then assumes the input power is actually used at that operating point. It is an energy-balance estimate rather than a manufacturer performance curve.

A pump operates where its curve meets the system curve. The tools here isolate a stated energy, displacement or test relationship; they do not automatically select a pump or verify suction conditions, cavitation margin, protection or installation requirements.

Check the numbers

Pump Flow from Power Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Input power at chosen boundary = 1 kW; Input-to-hydraulic efficiency = 70 %; Pump differential head = 20 m; Fluid density = 998 kg/m³.

OutputComputed result
Power-balance pump volume flow214.569544 L/min
Volume flow SI0.003576 m³/s
Volume flow hourly12.874173 m³/h
US liquid flow56.683277 US GPM
Cubic feet per minute7.577452 CFM

How one input changes the answer

ScenarioChanged inputResult
0.25 kWInput power at chosen boundary53.642386 L/min
0.5 kWInput power at chosen boundary107.284772 L/min
0.75 kWInput power at chosen boundary160.927158 L/min
1 kWInput power at chosen boundary214.569544 L/min
1.5 kWInput power at chosen boundary321.854316 L/min
2 kWInput power at chosen boundary429.139088 L/min
3 kWInput power at chosen boundary643.708631 L/min

Unchanged inputs use: Input power at chosen boundary = 1 kW; Input-to-hydraulic efficiency = 70 %; Pump differential head = 20 m; Fluid density = 998 kg/m³. Results retain the model limitations described above.

Common questions

Can I convert HP directly to GPM?

No. Supply head and efficiency as well as the actual power boundary.

Does pressure alone determine flow from a pump?

No. A pump curve and system relationship normally establish the operating point.

What if head is zero?

This inverse form would divide by zero and cannot determine a unique finite flow.

Should electrical or shaft kW be entered?

Use one consistent boundary and the matching efficiency for that boundary.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
  • Grundfos: pump curves, head and operating flowhttps://www.grundfos.com/uk/learn/research-and-insights/pump-curves