Flow rate calculators / Pumps & water systems
Measure flow. Understand the conditions.
Pump Affinity Laws Calculator
Scale a centrifugal-pump curve point for a speed change under stated similarity assumptions.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
At similar operation and unchanged diameter: Q₂/Q₁=n₂/n₁; H₂/H₁=(n₂/n₁)²; P₂/P₁=(n₂/n₁)³.
Scale a centrifugal-pump curve point for a speed change under stated similarity assumptions.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
No impeller-trimming guarantee, manufacturer approval or complete system intersection is supplied.
Pump Affinity Laws calculation: inputs and interpretation
The scaled point describes a homologous location on the pump characteristic. It is not automatically the new system operating point, especially when static head is significant. Efficiency, cavitation behavior and permissible speed can change.
A pump operates where its curve meets the system curve. The tools here isolate a stated energy, displacement or test relationship; they do not automatically select a pump or verify suction conditions, cavitation margin, protection or installation requirements.
Continue with: Pump Power Calculator · Pump Flow from Power Calculator · Displacement Pump Flow Calculator · Pool Turnover Flow Calculator
Check the numbers
Pump Affinity Laws Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Original flow = 100 L/min; Original head = 20 m; Original input power = 1 kW; Original speed = 1500 RPM; New speed = 1800 RPM.
| Output | Computed result |
|---|---|
| Similarity-scaled pump flow | 120 L/min |
| Scaled head | 28.8 m |
| Scaled power | 1.728 kW |
| Speed ratio | 1.2 ratio |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 450 RPM | New speed | 30 L/min |
| 900 RPM | New speed | 60 L/min |
| 1350 RPM | New speed | 90 L/min |
| 1800 RPM | New speed | 120 L/min |
| 2700 RPM | New speed | 180 L/min |
| 3600 RPM | New speed | 240 L/min |
| 5400 RPM | New speed | 360 L/min |
Unchanged inputs use: Original flow = 100 L/min; Original head = 20 m; Original input power = 1 kW; Original speed = 1500 RPM; New speed = 1800 RPM. Results retain the model limitations described above.
Common questions
Does a 20% speed increase mean 20% more power?
The ideal similarity power ratio is 1.2 cubed, about 1.728, under its assumptions.
Will actual system flow follow the same ratio?
Not necessarily. The new curve must intersect the actual system curve.
Can I use it for positive-displacement pumps?
Their displacement/slip relationship is different; use the displacement tool for that stated model.
Is every RPM mechanically permitted?
No. Check the real equipment limits and operating conditions.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- KSB Centrifugal Pump Lexicon: affinity laws and similarity conditionshttps://www.ksb.com/en-global/centrifugal-pump-lexicon/article/affinity-laws-1115682
- Grundfos: pump curves, head and operating flowhttps://www.grundfos.com/uk/learn/research-and-insights/pump-curves