Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Pipe hydraulics

Measure flow. Understand the conditions.

Hazen–Williams Flow Calculator

Estimate water flow in a full pipe from friction head and a supplied Hazen–Williams C coefficient.

Your flow inputs

mm
m
m
coefficient

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

SI Q = [head × C^1.852 × D^4.871 / (10.67 × length)]^(1/1.852).

Estimate water flow in a full pipe from friction head and a supplied Hazen–Williams C coefficient.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Use only within the empirical model’s appropriate water-flow conditions; other head components are excluded.

Hazen–Williams Flow calculation: inputs and interpretation

The numerical coefficient and exponents here use metres, seconds and m³/s internally. This is not a gas correlation, and C is not a Darcy friction factor. The default C is an example, not an assertion about every PVC, steel or aged pipe.

Pipe losses depend on the model and fluid condition. Inner diameter, roughness, temperature-dependent properties and fittings must be consistent. A result for one straight run does not solve a branched network, select a pressure rating or establish a safe maximum operating flow.

Check the numbers

Hazen–Williams Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Actual internal diameter = 50 mm; Straight pipe length = 20 m; Friction head available = 5 m; Hazen–Williams C = 140 coefficient.

OutputComputed result
Empirical Hazen–Williams water flow418.939235 L/min
Volume flow SI0.006982 m³/s
Volume flow hourly25.136354 m³/h
US liquid flow110.672038 US GPM
Cubic feet per minute14.794699 CFM

How one input changes the answer

ScenarioChanged inputResult
1.25 mFriction head available198.182201 L/min
2.5 mFriction head available288.142846 L/min
3.75 mFriction head available358.665426 L/min
5 mFriction head available418.939235 L/min
7.5 mFriction head available521.474059 L/min
10 mFriction head available609.107897 L/min
15 mFriction head available758.186249 L/min

Unchanged inputs use: Actual internal diameter = 50 mm; Straight pipe length = 20 m; Friction head available = 5 m; Hazen–Williams C = 140 coefficient. Results retain the model limitations described above.

Common questions

Can I enter PSI as the head?

Convert the appropriate pressure difference to water head first, using consistent fluid properties.

Is C the same as roughness height?

No. Hazen–Williams C is an empirical coefficient, not a length.

Can this model laminar or high-viscosity flow?

The empirical relationship may be unsuitable. Use an appropriate fluid-mechanics model instead.

Does this include fittings?

Not automatically. The form describes a straight-run friction budget.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US EPA: EPANET 2.2 hydraulic methods and reference manualhttps://www.epa.gov/water-research/epanet
  • US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf