Flow rate calculators / Pipe hydraulics
Measure flow. Understand the conditions.
Darcy–Weisbach Head Loss Calculator
Calculate straight-pipe friction head and pressure drop using an explicitly supplied Darcy factor.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Head loss = fD × (L/D) × v²/(2g); pressure loss = density × g × head loss.
Calculate straight-pipe friction head and pressure drop using an explicitly supplied Darcy factor.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
This straight-run model excludes elevation, fittings, entrance/exit and equipment losses unless calculated separately.
Darcy–Weisbach Head Loss calculation: inputs and interpretation
First obtain mean velocity from the full circular section, then apply the Darcy–Weisbach relationship. The factor is Darcy, not Fanning; using a Fanning number without conversion understates loss by four. Diameter is in metres internally and flow is in m³/s.
Pipe losses depend on the model and fluid condition. Inner diameter, roughness, temperature-dependent properties and fittings must be consistent. A result for one straight run does not solve a branched network, select a pressure rating or establish a safe maximum operating flow.
Continue with: Reynolds Number Calculator · Pressure to Flow Rate Calculator · Pipe Friction Factor Calculator · Hazen–Williams Flow Calculator
Check the numbers
Darcy–Weisbach Head Loss Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Volumetric flow = 60 L/min; Actual internal diameter = 50 mm; Straight pipe length = 20 m; Darcy friction factor = 0.02 ratio; Fluid density = 998 kg/m³.
| Output | Computed result |
|---|---|
| Straight-run friction head loss | 0.105799 m |
| Friction pressure loss | 1.035454 kPa |
| Friction pressure loss | 0.15018 psi |
| Average velocity | 0.509296 m/s |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 15 L/min | Volumetric flow | 0.006612 m |
| 30 L/min | Volumetric flow | 0.02645 m |
| 45 L/min | Volumetric flow | 0.059512 m |
| 60 L/min | Volumetric flow | 0.105799 m |
| 90 L/min | Volumetric flow | 0.238047 m |
| 120 L/min | Volumetric flow | 0.423194 m |
| 180 L/min | Volumetric flow | 0.952187 m |
Unchanged inputs use: Volumetric flow = 60 L/min; Actual internal diameter = 50 mm; Straight pipe length = 20 m; Darcy friction factor = 0.02 ratio; Fluid density = 998 kg/m³. Results retain the model limitations described above.
Common questions
What is the difference between Darcy and Fanning factors?
The Darcy factor is four times the Fanning factor. This form requires Darcy f.
Can I use Darcy–Weisbach for laminar flow?
Yes with the appropriate Darcy factor, such as 64/Re for fully developed Newtonian circular-pipe laminar flow.
Does this choose roughness automatically?
No. Supply a validated factor or use the friction-factor tool with suitable properties and roughness.
How does it differ from Hazen–Williams?
Darcy–Weisbach uses a friction factor and fluid properties. Hazen–Williams is an empirical water-flow relationship with a different coefficient.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
- US EPA: EPANET 2.2 hydraulic methods and reference manualhttps://www.epa.gov/water-research/epanet