Measure flow. Understand the conditions.

Hagen–Poiseuille Flow Calculator

Calculate steady fully developed laminar flow of a Newtonian fluid through a rigid circular tube.

Your flow inputs

Pa
mm
m
Pa·s

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Q = π × pressure drop × D^4 / (128 × dynamic viscosity × length).

Calculate steady fully developed laminar flow of a Newtonian fluid through a rigid circular tube.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

This is not a patient blood-flow, catheter-safety or physiological prediction model.

Hagen–Poiseuille Flow calculation: inputs and interpretation

The fourth-power diameter dependence belongs to a restrictive laminar model. Entrance effects, non-Newtonian behavior and tube compliance can invalidate it. Check Reynolds number using the resulting velocity and the actual density, which this formula does not require directly.

Pipe losses depend on the model and fluid condition. Inner diameter, roughness, temperature-dependent properties and fittings must be consistent. A result for one straight run does not solve a branched network, select a pressure rating or establish a safe maximum operating flow.

Check the numbers

Hagen–Poiseuille Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Pressure difference = 1000 Pa; Capillary internal diameter = 1 mm; Tube length = 1 m; Dynamic viscosity = 0.001 Pa·s.

OutputComputed result
Laminar rigid-tube theoretical flow0.001473 L/min
Average velocity0.03125 m/s
Volume flow SI2.454369e-8 m³/s
Volume flow hourly8.835729e-5 m³/h
US liquid flow0.000389 US GPM
Cubic feet per minute5.200514e-5 CFM

How one input changes the answer

ScenarioChanged inputResult
250 PaPressure difference0.000368 L/min
500 PaPressure difference0.000736 L/min
750 PaPressure difference0.001104 L/min
1000 PaPressure difference0.001473 L/min
1500 PaPressure difference0.002209 L/min
2000 PaPressure difference0.002945 L/min
3000 PaPressure difference0.004418 L/min

Unchanged inputs use: Pressure difference = 1000 Pa; Capillary internal diameter = 1 mm; Tube length = 1 m; Dynamic viscosity = 0.001 Pa·s. Results retain the model limitations described above.

Common questions

Can I use it for blood-flow restriction?

Not as a clinical model. Real blood vessels are compliant and pulsatile, and blood can depart from simple Newtonian assumptions.

Does doubling diameter double flow?

Under unchanged valid Poiseuille assumptions it increases theoretical flow sixteenfold.

Can I use turbulent pipe flow here?

No. Use an appropriate turbulent resistance model.

Why are SI units important?

Diameter is converted from mm to m internally; failing to convert before raising it to the fourth power produces a very large error.

Does this calculate renal plasma flow, renal blood flow or cardiac output?

No. Those require appropriate physiological measurements and validated clinical methods; this rigid Newtonian capillary equation does not implement clearance or Fick calculations.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf