Chromatography Linear Flow Calculator
Convert volumetric column flow into superficial linear velocity and an explicitly porosity-based estimate.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Superficial linear cm/h = mL/min × 60 / column area cm²; interstitial estimate = superficial velocity / porosity.
Convert volumetric column flow into superficial linear velocity and an explicitly porosity-based estimate.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
No resin capacity, pressure rating, packing method or official Cytiva product compatibility is determined.
Chromatography Linear Flow calculation: inputs and interpretation
The common chromatography linear-flow convention uses the whole column section. It is not necessarily the fluid velocity within connected pores. The separate interstitial estimate requires a meaningful porosity, and the two labels must not be mixed when scaling a process.
The inputs must describe the actual process boundary. Fluid properties, temperature or enthalpy change and equipment behavior can vary during operation. The displayed equations are preliminary calculations and do not implement proprietary equipment performance maps.
Continue with: Heating & Chilled Water Flow Calculator · Water Flow Heat Transfer Calculator · Steam Mass Flow from Heat Duty Calculator · Counterflow Heat Exchanger LMTD Calculator
Check the numbers
Chromatography Linear Flow Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Volumetric mobile-phase flow = 10 mL/min; Column internal diameter = 2 cm; Specified interstitial porosity = 0.4 ratio.
| Output | Computed result |
|---|---|
| Column superficial linear velocity | 190.985932 cm/h |
| Interstitial estimate | 477.464829 cm/h |
| Column section | 3.141593 cm² |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 2.5 mL/min | Volumetric mobile-phase flow | 47.746483 cm/h |
| 5 mL/min | Volumetric mobile-phase flow | 95.492966 cm/h |
| 7.5 mL/min | Volumetric mobile-phase flow | 143.239449 cm/h |
| 10 mL/min | Volumetric mobile-phase flow | 190.985932 cm/h |
| 15 mL/min | Volumetric mobile-phase flow | 286.478898 cm/h |
| 20 mL/min | Volumetric mobile-phase flow | 381.971863 cm/h |
| 30 mL/min | Volumetric mobile-phase flow | 572.957795 cm/h |
Unchanged inputs use: Volumetric mobile-phase flow = 10 mL/min; Column internal diameter = 2 cm; Specified interstitial porosity = 0.4 ratio. Results retain the model limitations described above.
Common questions
Does linear flow use centimetres per hour?
That is the readout here. mL equals cm³, and multiplying mL/min by 60 gives cm³/h.
Can I scale to a larger column at the same linear velocity?
The required volume flow scales with column cross-section under the corresponding process assumptions.
Is superficial velocity the same as pore velocity?
No. The latter additionally depends on a suitable porosity model.
Does this replace the resin instructions?
No. Product operating limits and process validation must be checked independently.
Can I use the column flow rate formula for HPLC?
It converts volumetric flow and cross-sectional area to superficial linear velocity. HPLC pressure, retention, separation performance and column compatibility need additional validated models and product limits; this geometric calculation does not supply them.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- Cytiva: chromatography flow-rate conversion between linear and volumetric flowhttps://www.cytivalifesciences.com/en/us/support/online-tools/chromatography/calculators/flow-rate
- US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html