Heating & Chilled Water Flow Calculator

Estimate liquid flow needed to carry a stated sensible heating or cooling duty.

Your flow inputs

kW
K
kg/m³
J/kg/K

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Water volume flow = thermal load W / (density × specific heat × positive temperature difference).

Estimate liquid flow needed to carry a stated sensible heating or cooling duty.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

No chiller, boiler, heat-pump or tankless-heater manufacturer performance is inferred.

Heating & Chilled Water Flow calculation: inputs and interpretation

The equation uses the magnitude of a temperature change and does not choose its sign or system arrangement. Water and glycol mixtures need appropriate density and specific heat. The familiar GPM/BTU/h shortcut embeds assumptions that may not fit another fluid or temperature.

The inputs must describe the actual process boundary. Fluid properties, temperature or enthalpy change and equipment behavior can vary during operation. The displayed equations are preliminary calculations and do not implement proprietary equipment performance maps.

Check the numbers

Heating & Chilled Water Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Thermal load magnitude = 10 kW; Positive water temperature difference = 5 K; Fluid density = 998 kg/m³; Specific heat = 4180 J/kg/K.

OutputComputed result
Sensible thermal-duty liquid flow28.765665 L/min
Volume flow SI0.000479 m³/s
Volume flow hourly1.72594 m³/h
US liquid flow7.599085 US GPM
Cubic feet per minute1.01585 CFM

How one input changes the answer

ScenarioChanged inputResult
2.5 kWThermal load magnitude7.191416 L/min
5 kWThermal load magnitude14.382833 L/min
7.5 kWThermal load magnitude21.574249 L/min
10 kWThermal load magnitude28.765665 L/min
15 kWThermal load magnitude43.148498 L/min
20 kWThermal load magnitude57.531331 L/min
30 kWThermal load magnitude86.296996 L/min

Unchanged inputs use: Thermal load magnitude = 10 kW; Positive water temperature difference = 5 K; Fluid density = 998 kg/m³; Specific heat = 4180 J/kg/K. Results retain the model limitations described above.

Common questions

Can I calculate GPM from MBH?

Yes after converting thermal units and specifying temperature change and fluid properties. The volume-flow result includes US GPM.

Does one cooling ton always require one fixed GPM?

No. The required flow also depends on temperature difference and fluid properties.

Can I use glycol?

Use validated mixture density and specific heat at the operating condition; none is looked up automatically.

Does this size a tankless water heater?

It is a thermal energy budget, not a complete appliance selection or installed-delivery guarantee.

How do I calculate cooling water flow rate using delta T?

For a stated sensible cooling duty, use mass flow = duty/(specific heat times temperature change), then divide by matching density. The inputs must describe the same fluid and operating range. This does not automatically select a cooling tower or chiller.

Can a tankless water heater GPM calculator use only the heater rating?

A temperature-rise target and a justified efficiency or delivered heat rating are also required. This page treats the entered duty as heat actually transferred to the water. A nameplate fuel input may need separate efficiency treatment.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 2: sensible heat and LMTDhttps://archives.standards.doxcelerate.com/documents/doe-hdbk-1012-2-92-thermodynamics-heat-transfer-and-fluid-flow-volume-2-of-3
  • NIST SP 811 Appendix B.9: volume, mass and flow unit factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9