Formula and calculation steps

Required active g/h = water m³/h × concentration increment mg/L; stock L/h = required g/h / active stock g/L.

Calculate a dilution/dosing volume balance from a specified active concentration increment.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Not a chemical treatment prescription, compatibility check or equipment approval.

Chemical Dosing Flow calculation: inputs and interpretation

The target increment must already be selected by a qualified process design. The stock input is active mass per litre, not an unconverted percentage or product name. Reaction demand, mixing, losses and a changing carrier flow can make a simple steady balance insufficient.

The inputs must describe the actual process boundary. Fluid properties, temperature or enthalpy change and equipment behavior can vary during operation. The displayed equations are preliminary calculations and do not implement proprietary equipment performance maps.

Check the numbers

Chemical Dosing Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Carrier water flow = 10 m³/h; Chosen concentration increment = 5 mg/L; Active stock concentration = 100 g/L.

OutputComputed result
Nominal active-stock dosing volume0.5 L/h
Required active mass50 g/h

How one input changes the answer

ScenarioChanged inputResult
2.5 m³/hCarrier water flow0.125 L/h
5 m³/hCarrier water flow0.25 L/h
7.5 m³/hCarrier water flow0.375 L/h
10 m³/hCarrier water flow0.5 L/h
15 m³/hCarrier water flow0.75 L/h
20 m³/hCarrier water flow1 L/h
30 m³/hCarrier water flow1.5 L/h

Unchanged inputs use: Carrier water flow = 10 m³/h; Chosen concentration increment = 5 mg/L; Active stock concentration = 100 g/L. Results retain the model limitations described above.

Common questions

Can I enter a product percentage as g/L?

Not without the appropriate density and active-ingredient conversion.

Does this choose the correct treatment dose?

No. The concentration increment is a supplied process input.

Does it account for background concentration?

Enter the justified additional active concentration, not an unadjusted final target when a background must be considered.

Does theoretical stock flow equal calibrated pump delivery?

Not necessarily. Verify the pump at actual conditions and the process measurement basis.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html
  • NIST SP 811 Appendix B.9: volume, mass and flow unit factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9