Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Pipe hydraulics

Measure flow. Understand the conditions.

Bernoulli Equation Calculator

Apply a stated incompressible energy balance to find a second-section gauge pressure.

Your flow inputs

kPa
m/s
m
m/s
m
m
kg/m³

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

p₂ = p₁ + ρ(v₁²−v₂²)/2 + ρg(z₁−z₂−specified loss).

Apply a stated incompressible energy balance to find a second-section gauge pressure.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

This simple balance does not check vapor pressure, cavitation, compressibility or a physiological blood-flow model.

Bernoulli Equation calculation: inputs and interpretation

The two sections must describe a consistent steady stream. Gauge pressures use the same reference, and both elevations share a datum. The entered loss is an external input, not calculated from pipe material. No pump or turbine head is included in this version.

Pipe losses depend on the model and fluid condition. Inner diameter, roughness, temperature-dependent properties and fittings must be consistent. A result for one straight run does not solve a branched network, select a pressure rating or establish a safe maximum operating flow.

Check the numbers

Bernoulli Equation Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Section 1 gauge pressure = 200 kPa; Section 1 average velocity = 1 m/s; Section 1 elevation = 0 m; Section 2 average velocity = 2 m/s; Section 2 elevation = 3 m; Specified loss between sections = 1 m; Fluid density = 998 kg/m³.

OutputComputed result
Modeled second-section pressure159.354853 kPa gauge
Pressure change-40.645147 kPa
Phase/cavitation statusNot assessed

How one input changes the answer

ScenarioChanged inputResult
0.5 m/sSection 2 average velocity161.226103 kPa gauge
1 m/sSection 2 average velocity160.851853 kPa gauge
1.5 m/sSection 2 average velocity160.228103 kPa gauge
2 m/sSection 2 average velocity159.354853 kPa gauge
3 m/sSection 2 average velocity156.859853 kPa gauge
4 m/sSection 2 average velocity153.366853 kPa gauge
6 m/sSection 2 average velocity143.386853 kPa gauge

Unchanged inputs use: Section 1 gauge pressure = 200 kPa; Section 1 average velocity = 1 m/s; Section 1 elevation = 0 m; Section 2 average velocity = 2 m/s; Section 2 elevation = 3 m; Specified loss between sections = 1 m; Fluid density = 998 kg/m³. Results retain the model limitations described above.

Common questions

Does higher velocity always mean lower pressure?

Only within the applicable energy balance when other energy terms and losses are correctly accounted for.

Can I enter different elevation datums?

No. The elevation difference must be meaningful in one common datum.

Does this model blood vessels?

No. It illustrates an incompressible energy equation, not pulsatile physiology or a clinical pressure assessment.

Where do fitting losses enter?

Include a justified equivalent head loss in the supplied loss input; they are not inferred automatically.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf