Compressor Receiver Fill Time Calculator
Estimate ideal isothermal receiver filling time from a constant reference-volume delivery.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Ideal time min = receiver L × (final−initial absolute kPa) / (reference kPa × free-air L/min).
Estimate ideal isothermal receiver filling time from a constant reference-volume delivery.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
Not a compressor capacity certification, thermal transient or pressure-vessel safety assessment.
Compressor Receiver Fill Time calculation: inputs and interpretation
The tank gas and reference gas are assumed to share a constant temperature with ideal behavior. Compressor delivery is referenced free-air volume, not compressed volume inside the receiver. Leakage, load cycling, rising temperature and changing delivery pressure can substantially alter actual time.
An airflow estimate does not certify indoor air quality or determine a code-required ventilation rate. Use the actual operating fan point, measurement plane and air density. Filter loading, duct losses, leakage and balancing can change delivered airflow.
Continue with: Airflow CFM Calculator · Air Changes to CFM Calculator · Bathroom Exhaust Fan Flow Calculator · Fan Power Calculator
Check the numbers
Compressor Receiver Fill Time Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Receiver internal volume = 100 L; Starting absolute pressure = 100 kPa abs; Final absolute pressure = 800 kPa abs; Free-air reference pressure = 101.325 kPa abs; Constant free-air delivery = 100 reference L/min.
| Output | Computed result |
|---|---|
| Ideal isothermal receiver fill duration | 6.908463 minutes |
| Required reference gas volume | 690.846287 L |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 25 reference L/min | Constant free-air delivery | 27.633851 minutes |
| 50 reference L/min | Constant free-air delivery | 13.816926 minutes |
| 75 reference L/min | Constant free-air delivery | 9.211284 minutes |
| 100 reference L/min | Constant free-air delivery | 6.908463 minutes |
| 150 reference L/min | Constant free-air delivery | 4.605642 minutes |
| 200 reference L/min | Constant free-air delivery | 3.454231 minutes |
| 300 reference L/min | Constant free-air delivery | 2.302821 minutes |
Unchanged inputs use: Receiver internal volume = 100 L; Starting absolute pressure = 100 kPa abs; Final absolute pressure = 800 kPa abs; Free-air reference pressure = 101.325 kPa abs; Constant free-air delivery = 100 reference L/min. Results retain the model limitations described above.
Common questions
Can I use a compressor displacement rating?
Only if it is a justified delivered reference-volume rate for this calculation; geometric displacement and free-air delivery differ.
Does the reference pressure need to be absolute?
Yes. The storage increment uses a pressure difference, while reference pressure is absolute.
Does this infer CFM from motor horsepower?
No. It requires the delivery rate as an input.
What if final pressure is below initial pressure?
That is not a positive receiver-filling interval and is rejected.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- NASA Glenn: conservation of mass, ideal gas and compressible nozzle flowhttps://www.grc.nasa.gov/www/k-12/airplane/mflchk.html
- NIST SP 811 Appendix B.9: volume, mass and flow unit factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9