Gas Cylinder Duration Calculator
Estimate an ideal isothermal gas-cylinder withdrawal duration with an explicit reserve.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Ideal available reference litres = cylinder litres × (start−reserve)/reference absolute pressure; duration = available litres / reference L/min.
Estimate an ideal isothermal gas-cylinder withdrawal duration with an explicit reserve.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
Not for choosing oxygen flow, neonatal FiO₂, veterinary therapy or a sole life-support endurance decision.
Gas Cylinder Duration calculation: inputs and interpretation
The temperature is assumed unchanged and compatible with the volume-rate reference; real-gas storage at high pressure can differ. The reserve is a user input rather than a therapy or safety requirement. A cylinder manufacturer’s rated usable content and approved device procedure take precedence.
Always distinguish absolute pressure from gauge pressure and absolute temperature from Celsius. Standard and normal volume rates require a stated reference condition. Real-gas properties, moisture and two-phase behavior are included only where explicitly described in the model.
Continue with: ACFM to SCFM Calculator · SCFM to ACFM Calculator · Gas Density Calculator · Compressible Gas Nozzle Calculator
Check the numbers
Gas Cylinder Duration Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Internal cylinder water volume = 10 L; Starting absolute pressure = 200 bar abs; Chosen reserve absolute pressure = 20 bar abs; Flow reference absolute pressure = 1 bar abs; Constant reference volume withdrawal = 5 reference L/min.
| Output | Computed result |
|---|---|
| Ideal isothermal withdrawal duration | 360 minutes |
| Ideal available reference volume | 1,800 L |
| Same duration | 6 hours |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 1.25 reference L/min | Constant reference volume withdrawal | 1,440 minutes |
| 2.5 reference L/min | Constant reference volume withdrawal | 720 minutes |
| 3.75 reference L/min | Constant reference volume withdrawal | 480 minutes |
| 5 reference L/min | Constant reference volume withdrawal | 360 minutes |
| 7.5 reference L/min | Constant reference volume withdrawal | 240 minutes |
| 10 reference L/min | Constant reference volume withdrawal | 180 minutes |
| 15 reference L/min | Constant reference volume withdrawal | 120 minutes |
Unchanged inputs use: Internal cylinder water volume = 10 L; Starting absolute pressure = 200 bar abs; Chosen reserve absolute pressure = 20 bar abs; Flow reference absolute pressure = 1 bar abs; Constant reference volume withdrawal = 5 reference L/min. Results retain the model limitations described above.
Common questions
Can I use this to choose an oxygen setting?
No. It provides gas arithmetic and does not prescribe oxygen, ventilation or patient care.
Does it account for high-pressure real-gas behavior?
No. The displayed storage approximation is ideal and isothermal.
What if reserve exceeds starting pressure?
No positive withdrawal interval exists under that input; the case is rejected.
Can I replace a certified cylinder duration table?
No. Use the actual rated content, regulator characteristics and required procedure for consequential use.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- NASA Glenn: conservation of mass, ideal gas and compressible nozzle flowhttps://www.grc.nasa.gov/www/k-12/airplane/mflchk.html
- NIST SP 811 Appendix B.9: volume, mass and flow unit factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9