The method

Formula and calculation steps

Ideal available reference litres = cylinder litres × (start−reserve)/reference absolute pressure; duration = available litres / reference L/min.

Estimate an ideal isothermal gas-cylinder withdrawal duration with an explicit reserve.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Not for choosing oxygen flow, neonatal FiO₂, veterinary therapy or a sole life-support endurance decision.

Gas Cylinder Duration calculation: inputs and interpretation

The temperature is assumed unchanged and compatible with the volume-rate reference; real-gas storage at high pressure can differ. The reserve is a user input rather than a therapy or safety requirement. A cylinder manufacturer’s rated usable content and approved device procedure take precedence.

Always distinguish absolute pressure from gauge pressure and absolute temperature from Celsius. Standard and normal volume rates require a stated reference condition. Real-gas properties, moisture and two-phase behavior are included only where explicitly described in the model.

Check the numbers

Gas Cylinder Duration Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Internal cylinder water volume = 10 L; Starting absolute pressure = 200 bar abs; Chosen reserve absolute pressure = 20 bar abs; Flow reference absolute pressure = 1 bar abs; Constant reference volume withdrawal = 5 reference L/min.

OutputComputed result
Ideal isothermal withdrawal duration360 minutes
Ideal available reference volume1,800 L
Same duration6 hours

How one input changes the answer

ScenarioChanged inputResult
1.25 reference L/minConstant reference volume withdrawal1,440 minutes
2.5 reference L/minConstant reference volume withdrawal720 minutes
3.75 reference L/minConstant reference volume withdrawal480 minutes
5 reference L/minConstant reference volume withdrawal360 minutes
7.5 reference L/minConstant reference volume withdrawal240 minutes
10 reference L/minConstant reference volume withdrawal180 minutes
15 reference L/minConstant reference volume withdrawal120 minutes

Unchanged inputs use: Internal cylinder water volume = 10 L; Starting absolute pressure = 200 bar abs; Chosen reserve absolute pressure = 20 bar abs; Flow reference absolute pressure = 1 bar abs; Constant reference volume withdrawal = 5 reference L/min. Results retain the model limitations described above.

Common questions

Can I use this to choose an oxygen setting?

No. It provides gas arithmetic and does not prescribe oxygen, ventilation or patient care.

Does it account for high-pressure real-gas behavior?

No. The displayed storage approximation is ideal and isothermal.

What if reserve exceeds starting pressure?

No positive withdrawal interval exists under that input; the case is rejected.

Can I replace a certified cylinder duration table?

No. Use the actual rated content, regulator characteristics and required procedure for consequential use.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • NASA Glenn: conservation of mass, ideal gas and compressible nozzle flowhttps://www.grc.nasa.gov/www/k-12/airplane/mflchk.html
  • NIST SP 811 Appendix B.9: volume, mass and flow unit factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9