Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Gas & compressed air

Measure flow. Understand the conditions.

Compressible Gas Nozzle Calculator

Estimate ideal-gas nozzle mass flow with automatic choked/nonchoked branch selection.

Your flow inputs

mm
kPa abs
kPa abs
°C
ratio
J/kg/K
ratio

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Ideal isentropic nozzle mass flow uses the pressure-ratio relation; below critical ratio [2/(gamma+1)]^[gamma/(gamma−1)], flow is choked.

Estimate ideal-gas nozzle mass flow with automatic choked/nonchoked branch selection.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Not an IEC/ISA control-valve model, relief-device design, real-gas pipeline or wet-steam calculation.

Compressible Gas Nozzle calculation: inputs and interpretation

The model uses upstream stagnation pressure and temperature with an effective opening and discharge coefficient. In the choked branch, further reducing the downstream pressure does not raise this ideal throat mass flow. The coefficient is not a substitute for a validated valve or nozzle calibration.

Always distinguish absolute pressure from gauge pressure and absolute temperature from Celsius. Standard and normal volume rates require a stated reference condition. Real-gas properties, moisture and two-phase behavior are included only where explicitly described in the model.

Check the numbers

Compressible Gas Nozzle Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Effective opening diameter = 5 mm; Upstream stagnation pressure = 500 kPa abs; Downstream pressure = 100 kPa abs; Upstream stagnation temperature = 20 °C; Specific heat ratio = 1.4 ratio; Specific gas constant = 287.05 J/kg/K; Effective discharge coefficient = 0.8 ratio.

OutputComputed result
Ideal-gas nozzle mass-flow estimate0.018539 kg/s
Mass per hour66.74042 kg/h
Pressure-ratio branchChoked ideal-nozzle branch
Critical downstream/upstream ratio0.528282 ratio
Actual pressure ratio0.2 ratio

How one input changes the answer

ScenarioChanged inputResult
25 kPa absDownstream pressure0.018539 kg/s
50 kPa absDownstream pressure0.018539 kg/s
75 kPa absDownstream pressure0.018539 kg/s
100 kPa absDownstream pressure0.018539 kg/s
150 kPa absDownstream pressure0.018539 kg/s
200 kPa absDownstream pressure0.018539 kg/s
300 kPa absDownstream pressure0.018327 kg/s

Unchanged inputs use: Effective opening diameter = 5 mm; Upstream stagnation pressure = 500 kPa abs; Downstream pressure = 100 kPa abs; Upstream stagnation temperature = 20 °C; Specific heat ratio = 1.4 ratio; Specific gas constant = 287.05 J/kg/K; Effective discharge coefficient = 0.8 ratio. Results retain the model limitations described above.

Common questions

Does this work for both choked and subsonic discharge?

It selects a pressure-ratio branch under the stated ideal-gas nozzle assumptions.

Can I use gauge pressures?

No. Both pressure inputs must be absolute.

Can I use this for steam through a valve?

Not as a complete steam-sizing method. Phase, real-fluid properties and valve-specific factors can be essential.

Does Cd remove every geometry limitation?

No. A single coefficient cannot make the ideal nozzle model valid for arbitrary devices or two-phase flow.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • NASA Glenn: conservation of mass, ideal gas and compressible nozzle flowhttps://www.grc.nasa.gov/www/k-12/airplane/mflchk.html