Flow rate calculators / Flow fundamentals
Measure flow. Understand the conditions.
Draining Tank Orifice Calculator
Integrate an ideal gravity-orifice discharge as the head falls in a constant-area tank.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Drain seconds = 2 tank area × (√h₁−√h₂) / [Cd × outlet area × √(2g)].
Integrate an ideal gravity-orifice discharge as the head falls in a constant-area tank.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
This does not model long discharge-pipe friction, trapped air, backpressure or changing tank area.
Draining Tank Orifice calculation: inputs and interpretation
Unlike a constant-flow emptying estimate, this model reduces outflow as the water level falls. The outlet discharges freely at the reference pressure, the tank is vented, and the plan area is much larger than the opening. Use a coefficient appropriate to the outlet geometry.
Keep the same time basis when comparing readings. A volume total, an average rate and an instantaneous meter value answer different questions. Use the actual wetted section or measured fluid quantity rather than an outside pipe dimension or an equipment nameplate that does not describe the operating condition.
Continue with: Flow Rate Calculator · Pipe Flow Rate Calculator · Flow Velocity Calculator · Pipe Diameter from Flow Calculator
Check the numbers
Draining Tank Orifice Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Constant tank plan area = 1 m²; Outlet orifice diameter = 20 mm; Initial water head above outlet = 1 m; Final water head above outlet = 0.1 m; Discharge coefficient = 0.62 ratio.
| Output | Computed result |
|---|---|
| Ideal falling-head drain time | 1,585.347818 seconds |
| Same duration | 26.422464 minutes |
| Initial discharge | 51.756887 L/min |
| Final discharge | 16.366965 L/min |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 0.25 m | Initial water head above outlet | 426.081809 seconds |
| 0.5 m | Initial water head above outlet | 906.265512 seconds |
| 0.75 m | Initial water head above outlet | 1,274.723427 seconds |
| 1 m | Initial water head above outlet | 1,585.347818 seconds |
| 1.5 m | Initial water head above outlet | 2,106.425998 seconds |
| 2 m | Initial water head above outlet | 2,545.715225 seconds |
| 3 m | Initial water head above outlet | 3,282.631055 seconds |
Unchanged inputs use: Constant tank plan area = 1 m²; Outlet orifice diameter = 20 mm; Initial water head above outlet = 1 m; Final water head above outlet = 0.1 m; Discharge coefficient = 0.62 ratio. Results retain the model limitations described above.
Common questions
Can the final head be zero?
Yes in this ideal integral. Actual near-empty behavior and outlet geometry may depart from the model.
What if the final head exceeds the starting head?
That is not a draining interval and is rejected.
Can I use a spherical tank?
Not with one constant plan area. Its area changes with level and requires a different integral.
Is Cd = 0.62 universal?
No. It is an illustrative coefficient, not a product calibration.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- US DOE Fundamentals Handbook, Thermodynamics, Heat Transfer and Fluid Flow, Volume 3https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL3.pdf
- US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html