Flow rate calculators / Flow fundamentals
Measure flow. Understand the conditions.
Rectangular Duct Flow Calculator
Calculate local volumetric flow through a rectangular duct or channel section of known area.
Your flow inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Q = internal width × internal height × average velocity.
Calculate local volumetric flow through a rectangular duct or channel section of known area.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
This does not determine fan static pressure, duct friction or a complete ventilation design.
Rectangular Duct Flow calculation: inputs and interpretation
Use dimensions at the same measurement plane as the velocity traverse. Insulation, lining or internal obstructions can reduce the free area. For an open rectangular channel, height means actual water depth rather than the total wall height.
Keep the same time basis when comparing readings. A volume total, an average rate and an instantaneous meter value answer different questions. Use the actual wetted section or measured fluid quantity rather than an outside pipe dimension or an equipment nameplate that does not describe the operating condition.
Continue with: Flow Rate Calculator · Pipe Flow Rate Calculator · Flow Velocity Calculator · Pipe Diameter from Flow Calculator
Check the numbers
Rectangular Duct Flow Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Internal width = 400 mm; Internal height = 250 mm; Area-averaged velocity = 3 m/s.
| Output | Computed result |
|---|---|
| Rectangular section volume flow | 18,000 L/min |
| Free area | 0.1 m² |
| Volume flow SI | 0.3 m³/s |
| Volume flow hourly | 1,080 m³/h |
| US liquid flow | 4,755.096942 US GPM |
| Cubic feet per minute | 635.664001 CFM |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 100 mm | Internal width | 4,500 L/min |
| 200 mm | Internal width | 9,000 L/min |
| 300 mm | Internal width | 13,500 L/min |
| 400 mm | Internal width | 18,000 L/min |
| 600 mm | Internal width | 27,000 L/min |
| 800 mm | Internal width | 36,000 L/min |
| 1200 mm | Internal width | 54,000 L/min |
Unchanged inputs use: Internal width = 400 mm; Internal height = 250 mm; Area-averaged velocity = 3 m/s. Results retain the model limitations described above.
Common questions
Can I calculate CFM from duct velocity?
Yes. The result includes CFM after applying the rectangular free area.
Can I use one anemometer reading?
Only if it is a justified area average. A traverse is often needed for a nonuniform profile.
Are millimetres squared already square metres?
No. Divide each millimetre dimension by 1,000 before multiplying to obtain m².
Does this include duct leakage?
No. It calculates flow at the stated section only.
Which assumptions should I verify?
Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.
Where are the formula sources?
Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html
- US Department of Energy: Improving Fan System Performance, pressure-flow power and fan lawshttps://www.energy.gov/sites/default/files/2014/05/f16/fan_sourcebook.pdf