Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Flow fundamentals

Measure flow. Understand the conditions.

Rectangular Duct Flow Calculator

Calculate local volumetric flow through a rectangular duct or channel section of known area.

Your flow inputs

mm
mm
m/s

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Q = internal width × internal height × average velocity.

Calculate local volumetric flow through a rectangular duct or channel section of known area.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

This does not determine fan static pressure, duct friction or a complete ventilation design.

Rectangular Duct Flow calculation: inputs and interpretation

Use dimensions at the same measurement plane as the velocity traverse. Insulation, lining or internal obstructions can reduce the free area. For an open rectangular channel, height means actual water depth rather than the total wall height.

Keep the same time basis when comparing readings. A volume total, an average rate and an instantaneous meter value answer different questions. Use the actual wetted section or measured fluid quantity rather than an outside pipe dimension or an equipment nameplate that does not describe the operating condition.

Check the numbers

Rectangular Duct Flow Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Internal width = 400 mm; Internal height = 250 mm; Area-averaged velocity = 3 m/s.

OutputComputed result
Rectangular section volume flow18,000 L/min
Free area0.1 m²
Volume flow SI0.3 m³/s
Volume flow hourly1,080 m³/h
US liquid flow4,755.096942 US GPM
Cubic feet per minute635.664001 CFM

How one input changes the answer

ScenarioChanged inputResult
100 mmInternal width4,500 L/min
200 mmInternal width9,000 L/min
300 mmInternal width13,500 L/min
400 mmInternal width18,000 L/min
600 mmInternal width27,000 L/min
800 mmInternal width36,000 L/min
1200 mmInternal width54,000 L/min

Unchanged inputs use: Internal width = 400 mm; Internal height = 250 mm; Area-averaged velocity = 3 m/s. Results retain the model limitations described above.

Common questions

Can I calculate CFM from duct velocity?

Yes. The result includes CFM after applying the rectangular free area.

Can I use one anemometer reading?

Only if it is a justified area average. A traverse is often needed for a nonuniform profile.

Are millimetres squared already square metres?

No. Divide each millimetre dimension by 1,000 before multiplying to obtain m².

Does this include duct leakage?

No. It calculates flow at the stated section only.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • US Bureau of Reclamation Water Measurement Manual, 2.4: discharge, area and velocityhttps://www.usbr.gov/tsc/techreferences/mands/wmm/chap02_04.html
  • US Department of Energy: Improving Fan System Performance, pressure-flow power and fan lawshttps://www.energy.gov/sites/default/files/2014/05/f16/fan_sourcebook.pdf