Flow Rate CalculatorLiquid, gas & engineering tools

Flow rate calculators / Flow fundamentals

Measure flow. Understand the conditions.

Mass Flow Rate Calculator

Calculate mass flow from local volumetric flow and a matching fluid density.

Your flow inputs

L/min
kg/m³

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Mass flow kg/s = density kg/m³ × volume flow m³/s.

Calculate mass flow from local volumetric flow and a matching fluid density.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

No automatic water, air, refrigerant, fuel or steam property table is supplied.

Mass Flow Rate calculation: inputs and interpretation

Density must describe the fluid at the same pressure, temperature and composition as the volume rate. A standard gas volume and an operating-condition density cannot be mixed without conversion. For a two-phase stream, a single assumed density can conceal a major error.

Keep the same time basis when comparing readings. A volume total, an average rate and an instantaneous meter value answer different questions. Use the actual wetted section or measured fluid quantity rather than an outside pipe dimension or an equipment nameplate that does not describe the operating condition.

Check the numbers

Mass Flow Rate Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Volumetric flow = 60 L/min; Fluid density = 998 kg/m³.

OutputComputed result
Mass flow at supplied density0.998 kg/s
Mass per hour3,592.8 kg/h
Mass per hour7,920.768156 lb/h

How one input changes the answer

ScenarioChanged inputResult
15 L/minVolumetric flow0.2495 kg/s
30 L/minVolumetric flow0.499 kg/s
45 L/minVolumetric flow0.7485 kg/s
60 L/minVolumetric flow0.998 kg/s
90 L/minVolumetric flow1.497 kg/s
120 L/minVolumetric flow1.996 kg/s
180 L/minVolumetric flow2.994 kg/s

Unchanged inputs use: Volumetric flow = 60 L/min; Fluid density = 998 kg/m³. Results retain the model limitations described above.

Common questions

How do I calculate air mass flow?

Use actual local volume flow and local air density, or a standard volume rate with its matching standard density.

Is kg/h interchangeable with L/h?

Only after specifying density. Equal numbers are not generally correct.

Can I use this for fuel mass flow?

Yes as arithmetic with the actual fuel density and matching volume condition.

How do I calculate steam mass flow?

Use a validated steam density for the actual state; this tool does not fetch steam tables or determine phase.

Which assumptions should I verify?

Check every unit, the observation period and the physical or reference-state boundary stated above. Starting inputs and computed examples are illustrative scenarios, not recommended settings, certified capacities or universal standards.

Where are the formula sources?

Published method and unit references appear at the bottom of this page as plain-text addresses. Computed tables use the same server calculation as the form. No external content-data file is needed at runtime.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • NASA Glenn: conservation of mass, ideal gas and compressible nozzle flowhttps://www.grc.nasa.gov/www/k-12/airplane/mflchk.html
  • NIST SP 811 Appendix B.9: volume, mass and flow unit factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9